The "top navigation" is hidden when using the page builder in order to maintain useability. To edit the topnav, please use the divi library.

Single Bearing

Exceptional performance and reliability, with consistent power for standby and continuous-duty industrial, marine, irrigation, mobile, or light-tower applications. WorldWide Electric AC synchronous generators, often called generator-ends or alternators, are interchangeable with Marathon, Stamford® Newage and Onan generators, as well as other generator manufacturers.

Description

Power Ratings

  • 4 – 2100 kW rated to 40°C, with models options 7.5 – 99 kW rated to 50°C* (CSA Approval Pending*)
  • Single-Phase or Three-phase
  • 60 Hz power at 1800 RPM
  • 50 Hz power at 1500 RPM

Model Options

  • 12 Lead, Three-Phase, 4 Pole, 60 Hz*
  • 12 Lead, Three-Phase, 4 Pole, 50 Hz
  • 4 Lead, Single-Phase, 4 Pole, 60 Hz
  • 4 Lead, Single-Phase, 4 Pole, 50 Hz

Applications

  • Pumping & Pivot Irrigation Systems
  • Mobile Generators
  • On-board (Marine) System Generators*

Features

All WorldWide Generators

  • Self-ventilated for reliability.
  • Designed and built per IEC 600341-1 & -2 requirements, BS4990 & 5000, NEMA MG1 2006, CSA, and CE and produced in an ISO-certified facility.
  • IP 22 Rated with Enhanced varnishing and epoxy coatings to withstand harsh environments.
  • Bolted diodes eliminate the need for a soldering iron to check rotating diodes in the field.
  • Stranded lead wires provide a more reliable conductor when changing output configuration.
  • Essex wire is used for improved reliability and performance.

Downloads

Filters

Model Number Ambient Temp RPM Phase Class H (125C) kW Class H (125C) kVA
50C1800Three-Phase120150
50C1800Three-Phase94117.5
50C1800Three-Phase80100
50C1800Three-Phase7087.5
50C1800Three-Phase5670
50C1800Three-Phase5062.5
50C1800Three-Phase4252.5
50C1800Three-Phase4050
50C1800Three-Phase37.546.9
50C1800Three-Phase3037.5
50C1800Three-Phase27.534.4
50C1800Three-Phase2328.8
50C1800Three-Phase1620
50C1800Three-Phase13.516.9
50C1800Three-Phase1113.8
50C1800Three-Phase8.210.2
40C1800Three-Phase11591449
40C1800Three-Phase9581197
40C1800Three-Phase10661332
40C1800Three-Phase8721090
40C1800Three-Phase766958
40C1800Three-Phase716895
40C1800Three-Phase640800
40C1800Three-Phase586732
40C1800Three-Phase500625
40C1800Three-Phase465581
40C1800Three-Phase370463
40C1800Three-Phase320400
40C1800Three-Phase288360
40C1800Three-Phase240300
40C1800Three-Phase225281
40C1800Single-Phase125156
40C1800Three-Phase196245
40C1800Three-Phase170213
40C1800Single-Phase120150
40C1800Three-Phase152190
40C1800Single-Phase108135
40C1800Three-Phase134.4168
40C1800Single-Phase90112
40C1800Single-Phase7796
40C1800Three-Phase120150
40C1800Single-Phase6784
40C1800Three-Phase94117.5
40C1800Three-Phase240300
40C1800Three-Phase80100
40C1800Single-Phase5670
40C1800Single-Phase4860
40C1800Three-Phase7087.5
40C1800Single-Phase4050
40C1800Three-Phase5670
40C1800Three-Phase5062.5
40C1800Single-Phase3544
40C1800Three-Phase4252.5
40C1800Single-Phase3037.5
40C1800Three-Phase4050
40C1800Single-Phase2835
40C1800Three-Phase37.546.9
40C1800Single-Phase2531.3
40C1800Three-Phase3037.5
40C1800Single-Phase2025
40C1800Single-Phase17.521.9
40C1800Three-Phase27.534.4
40C1800Single-Phase14.718.4
40C1800Three-Phase2328.8
40C1800Three-Phase1620
40C1800Single-Phase10.813.5
40C1800Three-Phase13.516.9
40C1800Single-Phase8.610.8
40C1800Three-Phase1113.8
40C1800Single-Phase78.8
40C1800Single-Phase5.16.4
40C1800Three-Phase8.210.2