Single Bearing

Exceptional performance and reliability, with consistent power for standby and continuous-duty industrial, marine, irrigation, mobile, or light-tower applications. WorldWide Electric AC synchronous generators, often called generator-ends or alternators, are interchangeable with Marathon, Stamford® Newage and Onan generators, as well as other generator manufacturers.

Description

Power Ratings

  • 4 – 2100 kW rated to 40°C, with models options 7.5 – 99 kW rated to 50°C* (CSA Approval Pending*)
  • Single-Phase or Three-phase
  • 60 Hz power at 1800 RPM
  • 50 Hz power at 1500 RPM

Model Options

  • 12 Lead, Three-Phase, 4 Pole, 60 Hz*
  • 12 Lead, Three-Phase, 4 Pole, 50 Hz
  • 4 Lead, Single-Phase, 4 Pole, 60 Hz
  • 4 Lead, Single-Phase, 4 Pole, 50 Hz

Applications

  • Pumping & Pivot Irrigation Systems
  • Mobile Generators
  • On-board (Marine) System Generators*

Features

All WorldWide Generators

  • Self-ventilated for reliability.
  • Designed and built per IEC 600341-1 & -2 requirements, BS4990 & 5000, NEMA MG1 2006, CSA, and CE and produced in an ISO-certified facility.
  • IP 22 Rated with Enhanced varnishing and epoxy coatings to withstand harsh environments.
  • Bolted diodes eliminate the need for a soldering iron to check rotating diodes in the field.
  • Stranded lead wires provide a more reliable conductor when changing output configuration.
  • Essex wire is used for improved reliability and performance.

Downloads

Filters

Model Number Ambient Temp RPM Phase Class H (125C) kW Class H (125C) kVA
50C1800Three-Phase120150
50C1800Three-Phase94117.5
50C1800Three-Phase80100
50C1800Three-Phase7087.5
50C1800Three-Phase5670
50C1800Three-Phase5062.5
50C1800Three-Phase4252.5
50C1800Three-Phase4050
50C1800Three-Phase37.546.9
50C1800Three-Phase3037.5
50C1800Three-Phase27.534.4
50C1800Three-Phase2328.8
50C1800Three-Phase1620
50C1800Three-Phase13.516.9
50C1800Three-Phase1113.8
50C1800Three-Phase8.210.2
40C1800Three-Phase11591449
40C1800Three-Phase9581197
40C1800Three-Phase10661332
40C1800Three-Phase766958
40C1800Three-Phase8721090
40C1800Three-Phase716895
40C1800Three-Phase640800
40C1800Three-Phase586732
40C1800Three-Phase500625
40C1800Three-Phase465581
40C1800Three-Phase370463
40C1800Three-Phase320400
40C1800Three-Phase288360
40C1800Three-Phase240300
40C1800Three-Phase225281
40C1800Single-Phase125156
40C1800Three-Phase196245
40C1800Three-Phase170213
40C1800Single-Phase120150
40C1800Three-Phase152190
40C1800Single-Phase108135
40C1800Three-Phase134.4168
40C1800Single-Phase90112
40C1800Three-Phase120150
40C1800Single-Phase7796
40C1800Single-Phase6784
40C1800Three-Phase94117.5
40C1800Three-Phase240300
40C1800Three-Phase80100
40C1800Single-Phase5670
40C1800Single-Phase4860
40C1800Three-Phase7087.5
40C1800Single-Phase4050
40C1800Three-Phase5670
40C1800Three-Phase5062.5
40C1800Single-Phase3544
40C1800Three-Phase4252.5
40C1800Single-Phase3037.5
40C1800Three-Phase4050
40C1800Single-Phase2835
40C1800Three-Phase37.546.9
40C1800Single-Phase2531.3
40C1800Three-Phase3037.5
40C1800Single-Phase2025
40C1800Single-Phase17.521.9
40C1800Three-Phase27.534.4
40C1800Single-Phase14.718.4
40C1800Three-Phase2328.8
40C1800Three-Phase1620
40C1800Single-Phase10.813.5
40C1800Three-Phase13.516.9
40C1800Single-Phase8.610.8
40C1800Three-Phase1113.8
40C1800Single-Phase78.8
40C1800Single-Phase5.16.4
40C1800Three-Phase8.210.2